Singapore legislation

Regulation 23

of Electric Vehicles Charging (Electric Vehicle Chargers) Regulations 2023

Regulation 23

Prescribed procedure and standard for inspection of EV charger

Subregulation 1

For the purposes of section 25(3)(a) of the Act, the procedure and standard for carrying out an inspection of an EV charger are prescribed in paragraphs (2), (3) and (4).

Subregulation 2

If the inspection is in respect of a fixed EV charger installed at a non‑restricted access location, a prescribed competent person must —

(a)

where the inspection relates to the first 6‑month period within every relevant period — carry out the inspection following the procedure and standard set out in either of the following applicable forms: (i)for a fixed EV charger with a power rating of more than 150 kilowatts that is equipped with a thermal management system — Form C of the LTA C&F List;

(ii)

for any other fixed EV charger — Form A of the LTA C&F List; and

(b)

where the inspection relates to the second 6‑month period within every relevant period —

(i)

carry out the inspection following the procedure and standard set out in either of the following applicable forms: (A)for a fixed EV charger with a power rating of more than 150 kilowatts that is equipped with a thermal management system — Form C of the LTA C&F List;

(B)

for any other fixed EV charger — Form A of the LTA C&F List; and

(ii)

obtain the written endorsement of a prescribed person that the procedure and standard set out in either of the following applicable forms have been complied with: (A)for a fixed EV charger with a power rating of more than 150 kilowatts that is equipped with a thermal management system — Form E of the LTA C&F List;

(B)

for any other fixed EV charger — Form D of the LTA C&F List.

Subregulation 3

If the inspection is in respect of a fixed EV charger installed at a restricted access location, a prescribed competent person must carry out the inspection following the procedure and standard set out in either of the following applicable forms: (a)for a fixed EV charger with a power rating of more than 150 kilowatts that is equipped with a thermal management system — Form C of the LTA C&F List;

(b)

for any other fixed EV charger — Form A of the LTA C&F List.

Subregulation 4

If the inspection is in respect of any non‑fixed EV charger, a prescribed competent person must carry out the inspection following the procedure and standard set out in Form B of the LTA C&F List.

Subregulation 5

For the purposes of paragraph (2) —

(a)

“relevant period” means any period of 12 months; and

(b)

the start date of the first relevant period is the day immediately after the date that the first lawful certification in respect of an EV charger was made under section 23 of the Act.