Singapore legislation
Regulation 8
Regulation 8
Particulars to be shown on building plans
All building plans shall, where applicable, consist of or contain the following:
a site plan showing —
the location and layout of the site with boundary lines clearly verged;
the outline of the building to be erected or building in which building works are to be carried out marked in colour or otherwise;
the north point, or the georeference, and the number of the lot and adjoining lots and the Mukim (MK) or Town Subdivision (TS) number of the lot;
the distance between the new building to be erected or the building works to be carried out and the lot boundary;
the retaining wall on the lot;
the existing and proposed platform levels and slopes; and
the ingress and egress to the site;
the floor plan of each storey including the roof plan of the building containing or showing —
clear statements indicating the purpose of every room or space in the building;
the types of materials to be used for the main elements of the buildings;
the grid lines or dimensions between columns, corridors, staircase landing and the thickness of walls and columns;
the type of plant, equipment or water tank proposed to be installed and the location of the equipment and every plant room or water tank room;
clear statements indicating every part of the building that is to be air-conditioned or mechanically ventilated;
in respect of the first storey, the existing and proposed platform levels of the site and adjoining lots; and
in respect of the first storey, the distance between the new building and the lot boundary; and
such other details or plans as the Commissioner of Building Control may require.